Products / AQN

AQN

Water and power for disaster zones

Disasters that result in blackouts and water emergencies can paralyze any area in the world. Unpredictability limits response times and the effectiveness of relief efforts. The AQN is a solution for overcoming countless scenarios where difficult terrain, large impact areas, limited accessibility to personnel and compromised water sources affect delivery of drinking water and electrical power.

The HydroVolt AQN can be deployed in minutes and has the versatility and portability to purify any water source: seawater, rivers, lakes, tap water, swimming pools, ponds and flood water. It can pump water out of flooded indoor areas even while providing standard generator applications.

No priming needed. Draws source water at constant flow from 91 meters (300 feet).

AQN
RO seawater
4,500 LPD · 1,200 GPD
RO fresh water
15,000 LPD · 4,000 GPD
Water pump
50,000 LPD · 14,500 GPD
Generator
YANMAR L70 · 4.5 kW

Capacity @ 220 V, 25 °C / 77 °F. Water filtration capacity (fresh water): 15,000 LPD (4,000 GPD).

Water purification stages

  1. Stage 1 & 2Particle pre-filter (stainless steel, on intake pump)
  2. Stage 3Reversible rinse-and-flush filter (80 micron)
  3. Stage 4Sediment filter (5 micron)
  4. Stage 5Carbon filter
  5. Stage 6Ultraviolet lamp (stainless steel frame)
  6. Stage 7Reverse osmosis desalination membranes (2)

4 modes of operation

  1. Power Generator Only

    The generator is capable of simultaneously powering the unit and offers usable external electricity. It can also be used as a stand-alone power generator.

  2. RO Water Maker / Purification

    Sea, brackish or nuclear/biologically/chemically contaminated water is processed using 7 stages, which include a reverse osmosis stage.

  3. Filter Only

    For less contaminated water sources, the reverse osmosis stage can be bypassed from the control panel, increasing the output to 15,000 L (4,000 gal) and extending the life of the RO membranes.

  4. Pump Only

    The powerful delivery pump can transfer over 50,000 L (14,500 gal) of water a day. This mode can be used to clear out flooded areas, provide showers, and rinse off equipment.

Key AQN features

Safety protection features

Specifications

Water control panel

  • Three pressure gauges
  • TDS display with water quality regulation
  • High-pressure pump regulator
  • Filtration water flowmeter
  • Reverse osmosis water flowmeter

Power control panel

  • Emergency master shut-off
  • Generator electric start
  • Two voltmeters
  • Two mode switches
  • Two hour counters
  • Circuit breakers
  • AC inlet
  • Two external power outlets

Power generator features

  • YANMAR L70 diesel generator, 4.5 kW
  • AVR (automatic voltage regulator), no power jump variations
  • Easy access to fuel tank from top, fuel level gauge
  • 2 outlets for powering external equipment (one 110 V or 220 V and one 12 V)
  • Electric key ignition start and recoil start, electric shut-down
  • LOW OIL engine protection
  • YANMAR oil capacity: 1.16 US qt (1 L)
  • Fuel tank capacity: 2.9 gal (11 L)
  • Battery type: 12 V gel cell
  • Battery capacity: 17 Ah (20 hr)

Body

  • 2 balanced hoist hooks for helicopter or crane lifting
  • 2 retractable wheelbarrow-style handles for rolling the unit
  • Stainless steel frame, ABS panels
  • 2 pneumatic aluminum wheels
  • Wheel size: 110/50-6.5

Hoses

  • Intake: 2 × 1" camlock, 10 m (32 ft)
  • Discharge: 2 × 1" camlock, 10 m (32 ft)
  • Pure water: 2 × camlock, 5 m (16 ft)
  • Extended range: 2 × 1" camlock, 10 m (32 ft)
  • Connectors: camlock on both ends of each hose, Military Standard Camlocks MIL-C-27487 (A-A-59326)
  • Heavy-duty hoses (20 bar / 290 psi)
  • Flush hose: quick connect with screen filter

Power supply

  • External or internal power production
  • 4.5 kW Yanmar L70-McAlte generator
  • Diesel

Dimensions & weight

  • Dimensions (L × W × H): 78 × 80 × 84 cm · 30.7 × 31.5 × 33 in
  • Handles extended: 60.6 cm, 23 in
  • Weight: 206 kg, 455 lbs (dry)
  • Noise (RO only): 82 dB(A) @ 23 ft

DX case specifications

  • Dimensions (L × W × H): 89 × 18 × 38 cm · 35 × 7 × 15 in
  • 'Wet' case: 23 kg / 51 lbs
  • 'Dry' case: 12 kg / 26 lbs
  • Body: ABS plastic, aluminum fixtures, stainless steel vent grilles (2)

Intake pump safety features

  • Auto shut-off & restart
  • Voltage load protection
  • Freeze protection

Intake pump specifications

  • Max head: 61 m, 200 ft
  • Max run: 91 m, 300 ft
  • Pump body material: stainless steel
  • Dimensions OD × L: 13 × 89 cm (5" × 35")
  • Weight (with cable): 12 kg / 26 lbs
  • Cable length: 10 m / 32 ft

Each unit comes with the following installed

  • Mesh screen sleeve
  • Large particle sleeve
  • Sediment and carbon filters
  • UV lamp
  • Two membranes
  • Camlock cover caps (3 in total)

'Dry' DX case includes

  • Water testing kit
  • AC power cord to unit (10 m)
  • Extended range extension cable (10 m)
  • QC camlock to garden hose adapter
  • Filter wrench
  • Unit cover
  • Plug adapter (GS-18 and SS-417 type)
  • User manual
  • Quick reference user guide
  • Source water evaluation sheet
  • Intake pump floater with stainless steel chains

'Wet' DX case includes

  • Stainless steel high-flow double-screen intake pump with cable (10 m)
  • Intake hose (10 m)
  • Discharge hose (10 m)
  • Pure water hose (5 m)
  • Extended range extension hose (10 m)
  • System flush / CIP hose with screen

Intake pump features

  • Vertical / horizontal operating position submersible stainless steel pump with handle and stainless steel / polyamide body
  • Motor: stainless steel (DIN W.-Nr. 1.4301) (ANSI 304)
  • Diameter: 16 cm (6.3") with handle, 13 cm (5") without handle
  • Can feed water to the AQN / SQN / AQS system at a range of over 90 meters (300 feet)
  • Pumps water out of flooded spaces at 10 gallons (38 liters) per minute with the 220 V model, and up to 14 gallons per minute with the 110 V model
  • 1" camlock installed for easy and quick connection to the intake hose
  • Pumps down to 3 inches from flooded rooms or vehicles